Universal Menu Book/Interface/Wireless options/Memorizing

From OptiWiki

Jump to: navigation, search

Memorizing options can be used to temporary store bar code data in case the bar code reader lost its connection. As soon the reader is connected again, the temporary stored data is transmitted to the computer and the storage area is cleared.

The data is stored in RAM. In case the battery is depleted or battery is removed, data is lost.

The bar code reader is automatically disconnected in case:

  • the bar code reader is out of range (too far away from cradle),
  • power from cradle is lost.

Data memorizing disabled:
Bar code data is not stored automatically, in case the connection is lost. Data memorizing can manually be started by reading the Start/continue memorizing option.

Data memorizing enabled:
Bar code data is stored automatically, in case the connection is lost.

Memorize after connection loss:
Data is only temporary stored in case the bar code reader lost its connection. Memorizing stops in case the +-DISC-+ label is read or in case the Bluetooth address is changed.

Always memorize when not connected:
Data is always temporary stored in case the bar code reader is not connected.

Memorize control labels:
The next options should be used without reading the SET and END label. These memorizing options are intended to manually control the memorizing mode.

Start/continue memorizing:
Manually start memorizing. In case memorized data was present, it will continue memorizing.

Stop/pause memorizing:
Manually stop memorizing. Memorizing can be continued by reading the Start/continue memorizing option.

Clear all memorized data:
All memorizing data is deleted and the storage area is cleared.

Transmit memorized data:
All memorized data will be transmitted, if a connection is available.

Available memory for memorizing is reader dependent (12kB).

SET Image:MenulabelZZ.png
Data memorizing disabled DTMD File:Menulabel DTMD.png
Data memorizing enabled DTME File:Menulabel DTME.png
Memorize after connection loss BM0 File:Menulabel BM0.png
Always memorize when not connected BM1 File:Menulabel BM1.png
END Image:MenulabelZZ.png
Clear all memorized data +-MCLR-+ File:Menulabel +-MCLR-+.png
Start/continue memorizing +-MSTR-+ File:Menulabel +-MSTR-+.png
Stop/pauze memorizing +-MSTP-+ File:Menulabel +-MSTP-+.png
Transmit memorized data +-MXMT-+ File:Menulabel +-MXMT-+.png