These options determine the buzzer type, tone, duration and loudness. The buzzer tone and loudness are reader dependent due to different buzzer types.
Buzzer type:
The buzzer may be disabled or enabled as either a hardware or software buzzer. Not all readers support both a hardware and software buzzer.
Buzzer tone:
If a software buzzer is used, the buzzer tone may be selected as shown in figure 6.01.
Buzzer duration and loudness:
If a software buzzer is used, a buzzer duration of 50, 100, 200 or 400 msec. may be selected. The loudness can be adjusted in four different steps.
Buzzer before transmission:
The good read buzzer will be activated after decoding the bar code, but before transmission. During the transmission the buzzer sequence will be completed.
Buzzer after transmission:
The good read buzzer will be activated after transmission.
Enable startup buzzer:
When this options is selected, the reader will generate a single good read buzzer to indicate the reader is ready after the reader is supplied with power.
Disable startup buzzer:
When this options is selected, the reader will not sound the buzzer after the reader is supplied with power.
| SET | | |
| Enable software buzzer | W8 | File:Menulabel W8.png |
| Enable hardware buzzer | W9 | File:Menulabel W9.png |
| Disable buzzer | W0 | File:Menulabel W0.png |
| Single tone buzzer | W1 | File:Menulabel W1.png |
| High - low buzzer | W2 | File:Menulabel W2.png |
| Low - high buzzer | W3 | File:Menulabel W3.png |
| Buzzer duration 50 msec. | W7 | File:Menulabel W7.png |
| Buzzer duration 100 msec. | W4 | File:Menulabel W4.png |
| Buzzer duration 200 msec. | W5 | File:Menulabel W5.png |
| Buzzer duration 400 msec. | W6 | File:Menulabel W6.png |
| Buzzer loudness: Maximum | T0 | File:Menulabel T0.png |
| Buzzer loudness: Loud | T1 | File:Menulabel T1.png |
| Buzzer loudness: Normal | T2 | File:Menulabel T2.png |
| Buzzer loudness: Minimum | T3 | File:Menulabel T3.png |
| Buzzer before transmission | VY | File:Menulabel VY.png |
| Buzzer after transmission | VZ | File:Menulabel VZ.png |
| Disable startup buzzer | GD | File:Menulabel GD.png |
| Enable startup buzzer | GC | File:Menulabel GC.png |