Universal Menu Book/Code options/Setting code specific options/Options for Maxicode
From OptiWiki
Maxicode is a fixed size matrix symbology with selectable error correction levels.
Maximum data capacity:
- alphanumeric data: 93 characters
- numeric data: 138 characters
Symbol size:
28.14mm wide * 26.91mm high (including quiet zones)
Error correction:
2 levels of Reed-Solomon error correction.
Additional features:
- Extended Channel Interpretation (ECI): support for different character sets and data interpretations.
- Structured append: represent data in up to 8 Maxicode symbols.
Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent.
Encodable characters:
- ASCII values 0 - 127 ( ISO 646 )
- ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII )
- With ECI: many other character sets
For string format see figure 3.44.
Options for Maxicode:
- Structured append time out: see read mode options.