C Language Development Kit/Loading software on the terminals/PHLxxxx

From OptiWiki

Jump to: navigation, search

Contents

Image

On all terminals from the PHL range runs an OS (operating system) and an application. The OS and the application can be loaded by a small PC application called APPLOAD.

Software codes
Each model of the PHLxxxx series has its own Operating System version that can be distinguished by an unique 3 letter code (starting with 'CB'). Before you try to load a new Operating System on a PHL terminal you have to know which Operating System file (i.e. CBWVxxxx.HEX for the PHL 2700) must be loaded on your terminal. In the table below you can find which software code belongs to which PHLxxxx terminal.
Terminal Code
PHL 1300 CBX
PHL 1700-1MB CBG
PHL 1700-2MB CBH
PHL 2700 CBW
PHL 1300
To load a new OS in the PHL 1300 and the cradle is used the cradle must be set in auto baudrate mode. For loading an application set the cradle in auto baudrate mode or in fixed 115200 baud.

Load OS

  • IrDA or Cradle
    • Make sure PHL 1300 is turned OFF.
    • Press [s]+[ENT]+[PW] keys at the same time.
    • Place the PHL 1300 in the cradle or before the IrDA adapter.
    • Select the OS by appload.

Load application

  • IrDA or Cradle
    • Press [1]+[.]+[PW] at the same time.
    • Select download appl from the system menu.
    • Place the PHL 1300 in the cradle or before the IrDA adapter.
    • Select the application to load by appload.
PHL 1700 1MB
PHL 1700 1MB
To load a new application in the PHL 1700 by the cradle, find the correct cradle dipswitch settings here. The baudrate settings to load application is 19200 baud.

Load OS

  • Direct cable
    • Make sure PHL 1700 is turned OFF.
    • Press [s]+[ENT]+[PW] keys at the same time.
    • Make sure direct cable is connected.
    • Select the OS by appload.
  • Cradle
    • Not possible.
  • IrDA
    • Not possible.

Load application

  • Direct cable
    • Press [0]+[7]+[PW] at the same time.
    • Select download appl from the system menu.
    • Select direct cable from download appl menu.
    • Select the application to load by appload.
  • Cradle
    • Press [0]+[7]+[PW] at the same time.
    • Select download appl from the system menu.
    • Select Cradle from download appl menu.
    • Select the application to load by appload.
  • IrDA
    • Press [0]+[7]+[PW] at the same time.
    • Select download appl from the system menu.
    • Select IrDA from download appl menu.
    • Select the application to load by appload.
PHL 2700
To load a new OS or application in the PHL 2700 by the cradle, set the cradle for loading an OS to 115200 baud. The baudrate settings to load application is 19200 baud.

Load OS

  • Direct cable
    • Make sure PHL 2700 is turned OFF.
    • Press [s]+[ENT]+[PW] keys at the same time.
    • Make sure direct cable is connected.
    • Select the OS by appload.
  • Cradle
    • Make sure PHL 2700 is turned OFF.
    • Press [s]+[ENT]+[TRIGGER]+[PW] keys at the same time.
    • Place the PHL2700 in the cradle.
    • Select the OS by appload.
  • IrDA
    • Make sure PHL 2700 is turned OFF.
    • Press [s]+[ENT]+[TRIGGER]+[PW] keys at the same time.
    • Place the PHL2700 before the IrDA adapter.
    • Select the OS by appload.

Load application

  • Direct cable
    • Make sure PHL 2700 is turned OFF.
    • Press [0]+[7]+[PW] at the same time.
    • Select download appl from the system menu.
    • Select direct cable from download appl menu.
    • Select the application to load by appload.
  • Cradle
    • Make sure PHL 2700 is turned OFF.
    • Press [0]+[7]+[PW] at the same time.
    • Select download appl from the system menu.
    • Select Cradle from download appl menu.
    • Select the application to load by appload.
  • IrDA
    • Make sure PHL 2700 is turned OFF.
    • Press [0]+[7]+[PW] at the same time.
    • Select download appl from the system menu.
    • Select IrDA from download appl menu.
    • Select the application to load by appload.